—Configurator

Specify a wall.

Every figure below is computed live from the same engineering model our estimators use. Change anything and watch all of it move. If the configuration is wrong for the room, it will tell you so.

SeriesHover or focus to compare

Best permanent indoor all-rounder

Corporate lobbies · Control rooms · Lecture theatres

Choose Core for dependable, front-serviceable walls built to stay put.

Pixel pitch
4.0 m
40 %
Ambient light
4.80 m1.35 m
1 px = 1.61′ of arc at 4.0 mWithin the design band
Full engineering specification for the configured wall
ParameterValueBasis
Active area4.80 × 1.35 m6.48 m²
Cabinets328 × 4 of 600 × 337.5 mm
Resolution2,560 × 720carries HD 720p 1:1
Total pixels1,843,2005,529,600 emitters
Diagonal196″aspect 3.56:1
Minimum distance1.88 mcloser than this, structure is obvious
Optimal band3.8–5.6 mthe range to design seating to
Fully merged6.45 m1 arcminute acuity limit
Service brightness600 nits40% of 1,500 peak
Peak power3.4 kW15 A at 230 V — size the breaker here
Average power1.1 kW3,469 kWh/year at 10 h × 6 days
Heat rejected3,794 BTU/hhand this to the mechanical engineer
Mass181 kgbefore mounting hardware
Signal chain3 ports4.6 Gbps at 60 Hz, 14-bit

Indicative supply-only rate

R 272,160

42,000 per m² × 6.48 m², excluding VAT. Cabinets, receiving cards and factory calibration only — no processing, rigging, structure, cabling, commissioning or spares. Those depend on the room, and we will not pretend otherwise by padding a percentage onto this figure.